T60
PV array · Meyer Burger Glass 390 bifacial · Totalp test site
Sun 14° · 218°
Output
14
kW
· 56 %
Energy so far
85
kWh
Front / rear irradiance
527 / 119
W/m²
Snow on modules
3
%
· 33 kWh lost
Alarms raised
0
Tilt / azimuth
60° / 185°
Front irradiance
527 W/m²
Rear irradiance
119 W/m²
Bifacial gain
+16.9 %
Snow on modules
3 %
Lost to snow
32 kWh
Last slide-off
10:26
Rated power
24 kWp
Output now
13.5 kW
Energy today
85 kWh
Lifetime
205 MWh
Availability
98.49 %
Runtime
5,810 h
Next service
in 833 h
Last seen
13:59:51
Total
120
Normal
119
Underperforming
1
Fault
0
Snow covered
0
Needing attention
R2-04B
Shaded by a snow cornice
Table 2 · column 4 · upper row
48 % of expected
UnderperformingTelemetry
Front irradiance
527.00 W/m²
Rear irradiance
119.00 W/m²
Module temperature
10.10 °C
Snow on modules
3.00 %
Wind gust
11.40 m/s
Snow load
2.53 kN/m²
String voltage
1,205.00 V
String current
7.51 A
Ambient
-3.10 °C
No alarms on this asset.