PV-01

PV array · Jinko Tiger Neo bifacial · Saflisch

Replay today
Live14:00
06:0008:0010:0012:00Now

Sun 15° · 217°

Producing

Output

720

kW

· 65 %

Energy so far

4,835

kWh

Front / rear irradiance

647 / 131

W/m²

Snow on modules

3

%

· 669 kWh lost

Alarms raised

0

ModulesUnderperforming2
Effective irradiance, W/m²0425850
Producing
Live
Now
Polled every 5 seconds; the 3D model follows these values unless you replay the day.
65% of rated

Tilt / azimuth

60° / 180°

Front irradiance

647 W/m²

Rear irradiance

131 W/m²

Bifacial gain

+15.2 %

Snow on modules

3 %

Lost to snow

669 kWh

Last slide-off

09:59

Rated power

1,100 kWp

Output now

719.7 kW

Energy today

4,835 kWh

Lifetime

1,436 MWh

Availability

98.89 %

Runtime

1,382 h

Next service

in 1,077 h

Last seen

13:59:46

Modules
Module health
Every module reports on its own. Hover one in the 3D view for its reading; faults blink red, underperforming modules blink amber.

Total

120

Normal

118

Underperforming

2

Fault

0

Snow covered

0

Needing attention

R1-07B

Hot spot on the front glass

Table 1 · column 7 · upper row

78 % of expected

Underperforming

R2-02B

Potential-induced degradation

Table 2 · column 2 · upper row

74 % of expected

Underperforming

Telemetry

Front irradiance

647.00 W/m²

Rear irradiance

131.00 W/m²

Module temperature

15.60 °C

Snow on modules

3.00 %

Wind gust

8.50 m/s

Snow load

2.18 kN/m²

String voltage

1,203.00 V

String current

8.80 A

Ambient

-0.60 °C

History
Power and snow-free potential
Active power against what the asset would make with clean modules. The gap is the snow loss.
Today
Hourly energy
MWh delivered and lost to snow, hour by hour since midnight.
Alarms
Asset alarms
Open and recent events for this asset.

No alarms on this asset.